Double circulation cooling
Continuous operation, base load, peak load
Code according to part II of DIN6271
MCXN
Overload capacity
10% according to DIN6271 (7.3.1.1) 1h / 12h
Environmental conditions
Air/Pressurized air cooling medium/atmospheric pressure/relative humidity:
45°C/32°C/0.1MPa
Rotational speed n
r/min
1200
1500
1800
Power Pr
kW
372
480
450
550
540
600
Mean effective pressure
MPa
1.4
1.81
1.36
1.66
1.36
1.51
Average piston speed
m/s
7.8
9.8
11.7
Fuel consumption rate
g/kW.h/
195
190
197
191
202
200
Description:
L MCFN Marine unlimited zone continuous operation fuel limit power, no overload capacity.
L MC20N Marine unlimited zone continuous operation of net effective power, up to 20% overload.
L ICXN ISO net effective power for continuous operation, up to 10% overload.
L ICFN ISO fuel limit power for continuous operation without overload capacity.
L +10% overload 10% power.
L +20% overload 10% power.
L 2H /12h Allows 2 hours of operation within 12 hours.
L 0.5h/6h Allowed to run 0.5 hours within 6 hours.
L 1h/12h Operation within 12 hours is allowed for 1 hour.
L 1000H /a Allows 1000 hours of operation within a year.